磁共振测量嗅球容积在阿尔茨海默病早期诊断中的价值
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


The early diagnositic value of olfactory bulb volume measurement with MRI to Alzheimer’ disease
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:研究阿尔茨海默病(Alzheimer’ disease,AD)嗅球容积变化,探讨嗅球容积测定用于AD早期诊断的可能性。方法:轻度AD患者及正常对照各31例,磁共振(magnetic resonance imaging,MRI)测量海马体积及嗅球容积,简易精神状态量表(mini-mental status examination,MMSE)评价整体认知功能,分析海马体积、嗅球容积与MMSE分值的关系。结果:轻度AD组嗅球容积(115.39 ± 5.76) mm3和经颅腔容积校正的嗅球容积(82.59 ± 7.85) mm3均明显小于正常对照组的(126.96 ± 9.79) mm3及(94.53 ± 9.88) mm3 (P < 0.01)。AD组嗅球容积与MMSE评分呈正相关(r = 0.49,P < 0.05)。轻度AD组海马体积(2.07 ± 0.30) mm3明显小于正常对照组(2.37 ± 0.35) mm3 (P < 0.01)。AD组海马体积与MMSE评分呈正相关(r = 0.44,P < 0.05)。AD组嗅球容积与海马体积呈正相关(r = 0.69,P < 0.01)。MRI测量嗅球容积诊断轻度AD的特异性和敏感性分别为0.65和0.78,测量海马体积诊断轻度AD的特异性和敏感性分别为0.91和0.74。结论:轻度AD患者嗅球容积明显缩小,并与认知功能减退正相关,但MRI测量嗅球容积诊断轻度AD的准确性不如测量海马体积。

    Abstract:

    Objective: To study the early diagnositic value of olfactory bulb volume measurement with MRI to Alzheimer’ disease. Methods: Total of 31 patients with Alzheimer’ disease(AD) and 31 healthy elderly control was measured about olfactory bulb volume and hippocampal volume with magnetic resonance imaging (MRI). Their congnition function were measured by mini-mental status examination(MMSE),relationship between MMSE and olfactory bulb volume or hippocampal volume were analyzed. Results: AD group was significantly atrophy compared with the controls in olfactory bulb volume and hippocampal volume(P < 0.01). The correlation in AD group was found between hippocampal volume and MMSE scores (r = 0.44,P < 0.05),and between olfactory bulb volume and MMSE scores (r = 0.49,P < 0.05). A significant correlation in AD group was found between olfactory bulb volume and hippocampal volume (r = 0.69,P < 0.01). The specificity and sensitivity of olfactory bulb volume measurement with MRI to Alzheimer’ disease are respectively 0.65 and 0.78. The specificity and sensitivity of hippocampal volume measurement with MRI to Alzheimer’disease are respectively 0.91 and 0.74. Conclusion: Olfactory bulb volume in patients with AD was significantly smaller,and has significant correlation with congnition function reduction,but the diagnostic accuracy of olfactory bulb volume measurement with MRI to AD is no better than that of hippocampal volume.

    参考文献
    相似文献
    引证文献
引用本文

俱西驰,屈秋民,张 明,郭晨光,吴 谦,杨 华,郭 峰,罗国刚,金晨旺.磁共振测量嗅球容积在阿尔茨海默病早期诊断中的价值[J].南京医科大学学报(自然科学版),2011,(9):1337-1340

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2011-03-15
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期: