DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Comparison between two commercial immunoassays:Dr. Fooke ALLERG-O-LIQ versus Phadia ImmunoCAPR System in detecting allergen-specific IgE and total IgE values
Author:
Affiliation:

Fund Project:

This study was supported by the Science and Technique Fund(2005B30601014)and the Industry Technology and Development Fund(2007B030701007)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    Abstract:

    Objective: Beside patient’s history and skin prick testing(SPT) the detection of specific IgE(sIgE) represents an important tool of allergy diagnostics. In recent years different technologies for the detection of sIgE have been developed. The objective of this study is the comparison of the ALLERG-O-LIQ with the ImmunoCAPR System using seven inhalant and four food allergens. Methods: Sera from patients were collected and tested for sIgE to inhalant(d1, d2, d5, i6, e1, e5 and m3) and food allergens(f1, f2, f24, f24) by ALLERG-O-LIQ(Dr. Fooke Laboratorien GmbH) and by ImmunoCAPR System(Phadia). Further, samples were also tested for total IgE in both systems. Results: Prevalence of positive test results varied between 0/20(f24) and 11/20(e5) for ALLERG-O-LIQ and between 3/18(f23) and 11/20(d1/d5) for ImmunoCAPR. The qualitative agreement between both methods was found between 75%(f24) and 100%(d2) depending on the allergen. Overall qualitative agreement for inhalant(n = 140), food(n = 78) and all allergens(n = 218) tested was 92.1%(kappa = 0.84), 83.3%(kappa = 0.58), 89.0%(kappa = 0.77), respectively. Sensitivity, specificity, positive predictive value(PPV), negative predictive value(NPV) and diagnostic efficiency(DE) were found at 88.2%, 95.8%, 95.2%, 89.6%, 92.1%(inhalant allergens), 62.5%, 92.6%, 78.9%, 84.7%, 83.3%(food allergens) and 81.5%, 94.4%, 91.5%, 87.5%, 89.0%(all allergens). Conclusion: Good to excellent qualitative agreement between ALLERG-O-LIQ and ImmunoCAPR for the detection of specific and total IgE could be observed. The degree of agreement depended on the allergen and was higher in the group of inhalant allergens. The ALLERG-O-LIQ System represents a reliable test for the detection of specific and total IgE.

    参考文献
    相似文献
    引证文献
引用本文

Baoqing Sun, Mahler Michael, Mei Jiang, Jing Li, Nanshan Zhong.[J].南京医科大学学报(自然科学版),2008,28(5):273-278

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2008-08-13
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期:
  • 出版日期: