Association between novel cardiac injury marker YKL ⁃ 40 and myocardial fibrosis of idiopathic inflammatory myopathy:accessed by 3.0 T cardiac magnetic resonance
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective:The current study aims to quantitatively detect myocardial fibrosis of idiopathic inflammatory myopathy(IIM) by 3.0 T cardiac magnetic resonance(CMR),and to analyze the association between myocardial fibrosis of IIM and cardiac injury marker chitinase-3-like protein 1(YKL-40),to explore the value of serum YKL-40 in reflecting the degree of myocardial fibrosis in IIM patients with myocardial injury. Methods:A total of 64 IIM patients who visited the First Affiliated Hospital of Nanjing Medical University between May 2018 and August 2022 were retrospectively included. All patients underwent 3.0T CMR scan and the expression level of serum YKL -40 was measured. We used Student’s t test,Mann -Whitney U test or chi square test to compare the difference of each index between the myocardial injury group and the non-myocardial injury group;Spearman correlation analysis and linear regression were used to analyze the association between serum YKL-40 and CMR parameters in IIM patients. Receiver-operating characteristic(ROC)curve was used to assess the value of YKL-40 in predicting myocardial fibrosis in IIM patients. Results: Compared with patients without myocardial injury,IIM patients with myocardial injury had higher age[(53.0 ± 13.0)year vs.(44.6 ±16.1)year],serum YKL-40 expression level[73.4(46.9,119.3)ng/mL vs. 48.1(22.5,65.1)ng/mL],native T1[(1 263.2 ± 50.3)ms vs. (1221.8 ± 59.3)ms],and extracellular volume(ECV)[(31.7 ± 5.6)% vs.(28.7 ± 3.2)%],but the left ventricular stroke volume index (LVSVI)was lower[(42.3 ± 10.2)mL/m2 vs.(49.0 ± 11.1)mL/m2 ](all P < 0.05). Serum YKL-40 was positively correlated with ECV(r= 0.373,P=0.004). Multiple linear regression analysis showed that serum YKL-40 was independently correlated with ECV. YKL -40> 68ng/mL(AUC=0.71,95% CI 0.58~0.84)predicted myocardial fibrosis in IIM with a sensitivity of 0.62 and specificity of 0.86. Conclusion:Serum YKL-40 may reflect the degree of myocardial fibrosis in IIM patients with myocardial injury.

    Reference
    Related
    Cited by
Get Citation

汤映红,戴嘉懿,钱炜,杜梦迪,陆凤云,刘王琰,冯长静,孙晓萱,祝因苏,王嫱,周蕾.3.0T心脏磁共振对特发性炎症性肌病心肌纤维化与新型心脏损伤标志物YKL⁃40的关系研究[J].南京医科大学学报(自然科学版英文版),2023,(8):1115-1120.

Copy
Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:February 17,2023
  • Revised:
  • Adopted:
  • Online: August 10,2023
  • Published:
Article QR Code