Study on quantitative parameters of spectral CT in predicting central lymph node metastasis in patients with preoperative clinical lymph node-negative papillary thyroid carcinoma
CSTR:
Author:
Affiliation:

1Department of Radiology, the First Affiliated Hospital of Nanjing Medical University, Nanjing 210029 ; 2. Department of Radiology, Nanjing Central Hospital, Nanjing 210008 ; 3. Department of Thyroid Surgery, the First Affilited Hospital of Nanjing Medical University, Nanjing 210029 , China

Clc Number:

R814.42

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective: To evaluate the predictive efficacy of spectral CT quantitative parameters for central lymph node metastasis (CLNM) in preoperative clinical node-negative (cN0) papillary thyroid carcinoma (PTC) patients. Methods: Clinical and imaging data of 86 surgical pathologically confirmed PTC patients who underwent preoperative spectral CT imaging, were retrospectively collected. Differences in clinical and spectral CT features between the CLNM and non-CLNM groups were compared. Receiver operating characteristic (ROC) curve analysis was used to assess the predictive performance of clinical features, spectral CT features, and a combined model, with area under the curve (AUC), sensitivity, and specificity calculated. Results: Among clinical indicators, sex, thyroglobulin (Tg) level, and cystic changes showed statistically significant differences between CLNM and non-CLNM groups (all P < 0.05). Among non-contrast (NC) spectral CT parameters, 40 keVHU and 70 keVHU values were significantly lower in CLNM group (all P < 0.05). Among arterial phase (AP) spectral CT parameters, all parameters except arterial normalized effective atomic number (NZeff) differed significantly between two groups (all P < 0.05). Among venous phase spectral CT parameters, 70 keVHU value was significantly lower in CLNM group (P=0.014). Combined model demonstrated the highest predictive efficacy (AUC=0.896, sensitivity=86.7%, specificity=80.4% ), followed by spectral CT quantitative parameter model (AUC=0.835, sensitivity=73.3%, specificity=85.7% ), and clinical model (AUC=0.591, sensitivity=20.0%, specificity=98.2% ; all P < 0.05). Conclusion: Spectral CT quantitative parameters based on lesion characteristics improve the preoperative prediction of CLNM in cN0 PTC patients, and aid in treatment plan.

    Reference
    Related
    Cited by
Get Citation

CHAI Tingting, ZHOU Yan, SU Guoyi, SI Yan, SHEN Meiping, WU Feiyun, XU Xiaoquan. Study on quantitative parameters of spectral CT in predicting central lymph node metastasis in patients with preoperative clinical lymph node-negative papillary thyroid carcinoma[J].,2026,46(6):903-910.

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:March 07,2026
  • Revised:April 24,2026
  • Adopted:April 27,2026
  • Online: June 15,2026
  • Published:
Article QR Code