Biomechanical research of combined fixation with multiple locking plate osteosynthesis for hyperextension tibial plateau fractures
CSTR:
Author:
Affiliation:

Department of Orthopaedics, the Affiliated People's Hospital of Jiangsu University, Zhenjiang 212000 ;School of Medicine, Jiangsu University, Zhenjiang 212013 , China

Clc Number:

R681.8

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    Objective: To evaluate the differences in biomechanical performance of using multiple locking plate osteosynthesis for hyperextension tibial plateau fracture(HTPF). Methods: HTPF models were constructed using standardized artificial biomimetic tibia. Six plate fixation schemas were assembled: anterolateral, anteromedial, anterolateral + anteromedial, anteromedial + posteromedial, anterolateral+posteromedial, and tri-plate schema. Nine models were subjected to longitudinal loads of 250, 500, 1 000, and 1 500 N applied to the superior surface of the tibial plateau. The comprehensive displacement for each fixation schema was calculated using a three-dimensional camera system. Nine models were subjected to a uniform rotation of the proximal bone segment at a constant angular velocity of 0.5°/s. The torque required to achieve 10° of internal rotation and 10° of external rotation was recorded for each fixation schema. A repeated-measures analysis of variance was employed to assess the effects of fixation modality, compression(rotation), and their interactions on internal fixation outcomes. Pairwise comparisons were performed via paired t-tests, with multiple comparison adjustments implemented using the Bonferroni correction. Additionally, the paired standardized effect size (Cohen's d) and its 95% confidence interval were calculated. Results: The axial load tests revealed that the greater the applied pressure, the larger the overall displacement. When the axial load was 1500 N, the comprehensive displacement values of the groups of fixation schemas were as follows: anterolateral (5.16 ± 2.39) mm>anteromedial (4.04 ± 1.40) mm>anterolateral + anteromedial (2.56 ± 0.57) mm>anteromedial + posteromedial(1.75±0.71)mm>anterolateral+posteromedial(0.70±0.27)mm>tri-plate schema(0.34±0.10)mm. The horizontal rotation tests revealed that the average torque required for a ±10° rotation was as follows: anterolateral(9.87±2.07)N·m0.05); by contrast, the torque value of Group 5 was significantly higher than that of Group 4(P<0.05). Conclusion:For HTPF with intact articular surfaces, the fixation efficacy of locking plates increases with the number of plates used. Under the model and loading conditionsof this study, the dual-plate schema combining anterolateral and posteromedial plates exhibited smaller displacement and numerically higher torsional resistance, indicating a potential advantage in fixation performance.

    Reference
    Related
    Cited by
Get Citation

Yao Xiang, Pan Weijie, Zhong Zheng, Xu Yong. Biomechanical research of combined fixation with multiple locking plate osteosynthesis for hyperextension tibial plateau fractures[J].,2026,46(11):1704-1713.

Copy
Related Videos

Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:January 15,2026
  • Revised:June 30,2026
  • Adopted:
  • Online: November 15,2026
  • Published:
Article QR Code