Page 101 - 南京医科大学自然版
P. 101
第46卷第11期万云天,陈志林,崔筱洁,等. 基于双层探测器CT引导标注的3D nnU⁃Net模型在非增强CT食管分割中的应用:
2026年11月 与Total Segmentator模型的对比研究[J]. 南京医科大学学报(自然科学版),2026,46(11):1682-1690·1687 ·
(mm 3 ) 10 000.00 n=300 5 162.883 (mm 3 ) 5 000.00 0 n=100 Mean value (mm 3 ) 10 000.00 n=48 4 623.099
A B C
+1.96SD
+1.96SD
1 852.136
+1.96SD
Internal validation set -10 000.00 0 -10 436.183 Internal validation set -10 000.00 -12 830.236 Internal validation set -10 000.00 0 Mean value
-5 489.050
Mean value
-5 000.00
-2 607.292
-1.96SD
-2 636.650
-1.96SD
-1.96SD
-15 000.00
-9 837.682
35 000.00
45 000.00
10 000.00 30 000.00 50 000.00 20 000.00 30 000.00 40 000.00 50 000.00 20 000.00 30 000.00 40 000.00 50 000.00
60 000.00
40 000.00
20 000.00
25 000.00
24 000.00
35 000.00
45 000.00
Mean volume of the internal Mean volume of external Mean volume of external
validation set(mm ) test set 1(mm ) test set 2(mm )
3
3
3
(mm 3 ) 10 000.00 n=300 8 118.064 (mm 3 ) 5 000.00 0 n=100 Mean value (mm 3 ) 10 000.00 n=48 10 612.410
D E +1.96SD F
4 928.976
+1.96SD
+1.96SD
Internal validation set -10 000.00 0 -12 273.428 Internal validation set -10 000.00 -17 285.176 Internal validation set -10 000.00 0 -13 266.584
Mean value
Mean value
-6 178.100
-5 000.00
-1 327.083
-2 077.682
-1.96SD
-1.96SD
-1.96SD
-15 000.00
35 000.00
20 000.00
25 000.00
10 000.00 30 000.00 50 000.00 20 000.00 30 000.00 40 000.00 50 000.00 20 000.00 30 000.00 40 000.00 50 000.00
35 000.00
45 000.00
45 000.00
24 000.00
60 000.00
40 000.00
Mean volume of the internal Mean volume of external Mean volume of external
validation set(mm ) test set 1(mm ) test set 2(mm )
3
3
3
A:Limits of agreement between volumetric measurements from the 3D nnU⁃Net and manual delineations in the internal validation cohort. B:Limits
of agreement between volumetric measurements from the 3D nnU⁃Net and manual delineations in external validation cohort 1. C:Limits of agreement be⁃
tween volumetric measurements from the 3D nnU⁃Net and manual delineations in external validation cohort 2. D:Limits of agreement between volumet⁃
ric measurements from Total Segmentator and manual delineations in the internal validation cohort. E:Limits of agreement between volumetric measure⁃
ments from Total Segmentator and manual delineations in external validation cohort 1. F:Limits of agreement between volumetric measurements from
Total Segmentator and manual delineations in external validation cohort 2.
图2 模型分割体积与人工分割的Bland⁃Altman一致性分析
Figure 2 Bland⁃Altman analysis of volumetric segmentation between model and manual segmentation
表3 两名放射科医师对 3D nnU⁃Net 与 Total Segmentator 的主观评估结果
Table 3 Subjective evaluation of 3D nnU⁃Net and Total Segmentator by two radiologists
Radiologist Dataset 3D nnU⁃Net Total Segmentator Z P
Radiologist A Internal validation set 5.00(5.00,5.00) 2.00(2.00,2.00) 23.308 <0.001
External test set 1 5.00(4.00,5.00) 2.00(1.00,2.00) 12.787 <0.001
External test set 2 5.00(5.00,5.00) 1.00(1.00,2.00) 8.985 <0.001
Radiologist B Internal validation set 5.00(5.00,5.00) 2.00(2.00,2.00) 23.270 <0.001
External test set 1 5.00(4.25,5.00) 2.00(1.00,2.00) 12.819 <0.001
External test set 2 5.00(5.00,5.00) 1.00(1.00,2.00) 8.948 <0.001
ICC Internal validation set 0.794 0.976 - -
External test set 1 0.946 0.976 - -
External test set 2 0.960 0.786 - -
在训练阶段,创新性引入 DLCT 融合引导标注 根本上避免了分次扫描导致的人工金标准与训练图
策略。该策略通过单次CECT扫描同步生成VNC图 像配准偏差,降低了系统性误差。结合3D fullres对
像,二者融合后可借助 CECT 清晰区分食管与毗邻 食管管腔形态特征捕捉,该策略同时减少了nnU⁃Net
结构,有效缓解 NCCT 图像中食管因自身形态特点 监督学习中因训练数据不准确导致的模型性能下
导致的人工金标准难度大的问题;同时,二者源自 降,最终在 1 000 轮次的训练中,收敛优异(图 4)。
同一扫描时相及呼吸状态,可实现空间解剖信息完 该策略证实,DLCT⁃VNC图像训练的食管分割模型,
全一致,且通过VNC替代TNC图像进行模型训练,从 可在 NCCT 图像中实现稳定、高精度的分割,为

