Page 132 - 南京医科大学自然版
P. 132
第46卷第11期
·1718 · 南 京 医 科 大 学 学 报 2026年11月
次随访时的 DASH 评分显著低于平行组,差异有统 定引起局部皮肤刺激症状相关。垂直组典型病例
计学意义(P < 0.05,表 3),可能与平行组出现内固 见图1,平行组典型病例见图2。
表3 两组临床疗效比较
Table 3 Comparison of clinical efficacy between the two groups
Variable Vertical group(n=15) Parallel group(n=13) t/Z P
Constant⁃Murley score(x ± s) 95.5 ± 6.3 94.1 ± 5.9 0.604 0.551
DASH score(x ± s) 01.6 ± 0.2 02.1 ± 0.3 -5.254 < 0.001
Rockwood score(x ± s) 13.8 ± 0.6 13.5 ± 0.7 1.222 0.233
Rockwood excellent⁃good rate[n(%)] -0.152 0.879
Excellent 13(86.7) 11(84.6)
Good 02(13.3) 02(15.4)
Moderate 0(0) 0(0)
A B
41⁃year⁃old male patient with a proximal left clavicle fracture caused by falling from height,fixed by vertical double plates technique. A:Preoperative
three⁃dimensional(3D)reconstruction of the fracture site. B:Postoperative radiograph confirming satisfactory fracture reduction and appropriate fixation
placement of the vertical double plates.
图1 垂直双钢板技术固定患者1例
Figure 1 A patient fixed by vertical double plates technique
A B
37⁃year⁃old male patient with a proximal left clavicle fracture caused by a road traffic accident ,fixed by parallel double plates technique.
A :Preoperative three⁃dimensional(3D)reconstruction of the fracture site. B:Postoperative radiograph confirming satisfactory fracture reduction and
appropriate fixation placement of the parallel double plates.
图2 平行双钢板固定患者1例
Figure 2 A patient fixed by parallel double plates technique
道有接近10%的骨折不愈合率和接近50%的肩关节
3 讨 论
疼痛和僵硬的发生 [1-3,13] 。因此近年来对有移位的
锁骨近端骨折在临床上较罕见,多因高能量暴 锁骨近端骨折行手术内固定治疗已逐渐成为共识。
力直接损伤导致,常合并多发肋骨骨折、肺挫伤、血 目前锁骨近端骨折的手术方式多种多样,包括
气胸等。既往由于 X 线平片诊断困难,常发生漏 运用克氏针张力带、钢板螺钉内固定(锁骨钩钢板、
诊。锁骨近端骨折既往以保守治疗为主,但文献报 同侧锁骨远端钢板倒置、桡骨远端万向锁定钢板、