基于压缩感知的3D CS⁃SPACE序列在肩锁关节损伤诊断中的应用价值
作者:
作者单位:

1.南京医科大学第一附属医院放射科,江苏 南京 210029 ; 2.西门子数字医疗科技(上海)有限公司应用培训部,上海 200120

作者简介:

通讯作者:

中图分类号:

R445.2;R684

基金项目:

国家自然科学基金(81701652)


Application value of 3D CS ⁃ SPACE sequence based on compressed sensing in the diagnosis of acromioclavicular joint injury
Author:
Affiliation:

1.Department of Radiology,the First Affiliated Hospital of Nanjing Medical University,Nanjing 210029 ; 2.CustomerService Application,Siemens Healthineers Digital Technology(Shanghai)Co.Ltd.,Shanghai 200120 ,China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:探讨三维可变翻转角快速自旋回波(sampling perfection with application optimized contrast using different flip angle evolution,SPACE)序列联合压缩感知(compressed sensing,CS)技术在肩锁关节损伤诊断中的应用价值。方法:前瞻性地纳入2023年5月—2024年2月在南京医科大学第一附属医院就诊的有肩部外伤史、临床怀疑肩锁关节损伤的患者34例,对患者分别进行常规二维(two-dimension,2D)磁共振序列和基于CS的3D CS-SPACE序列扫描。分别在两组图像上测量肱二头肌长头腱和肱骨骨髓腔的信号强度和标准差,并计算出信噪比(signal to noise ratio,SNR)、对比噪声比(contrast to noise ratio, CNR);3位医生分别通过两组图像评估肩锁关节的损伤情况并给出其诊断信心评级。比较两组图像骨髓腔、肱二头肌长头腱的SNR、CNR以及诊断信心评级;分别分析3位医生在常规2D图像中的诊断一致性和3D CS-SPACE图像中的诊断一致性,最后评估两组图像之间的诊断一致性。结果:图像质量的客观评价中,3D CS-SPACE图像的SNR和CNR均明显优于常规2D图像;两组图像诊断信心的评级,2位医生的3D CS-SPACE图像评级明显高于常规2D图像,1位医生评级差异无统计学意义;3位医生在常规2D图像和3D CS-SPACE图像上对肩锁关节损伤的评估均具有较高的一致性(κ均>0.6),两组图像对肩锁关节的损伤评估具有较高的一致性(κ均>0.6)。结论:对于肩锁关节损伤的诊断,3D CS-SPACE图像与常规2D图像具有较高的一致性, 且3D CS-SPACE序列能够在缩短扫描时间的同时获得更好的图像质量。

    Abstract:

    Objective:To assess the value of sampling perfection with application optimized contrast using different flip angle evolution(SPACE)sequence combined with compressed sensing(CS)technique in the diagnosis of acromioclavicular joint injury. Methods:Total 34 patients with a history of shoulder trauma and suspected acromioclavicular joint injury in the First Affiliated Hospital of Nanjing Medical University were prospectively included form May,2023 to February,2024. Conventional 2D magnetic resonance sequence and 3D CS-SPACE sequence scanning based on CS were performed on the patients. Signal intensity and standard deviation of long head tendon of biceps and bone marrow cavity of humerus were measured on two sets of images,and SNR and CNR were calculated. Three doctors assessed the injuries of the acromioclavicular joint through two sets of images and gave their diagnostic confidence rating. The SNR,CNR of bone marrow cavity and biceps long tendon,and diagnostic confidence ratings were compared between the two groups. The diagnostic consistency of the three doctors in conventional 2D images and 3D CS - SPACE images was analyzed respectively,and the diagnostic consistency between the two sets of images was evaluated. Results:In the objective evaluation of image quality,SNR and CNR of 3D CS-SPACE image were obviously better than that of conventional 2D image. For the two groups of images,two doctors’ratings of 3D CS-SPACE images were significantly higher than those of conventional 2D images,and one doctor’s ratings had no significant difference. The three doctors demonstrated a strong agreement in the evaluation of acromioclavicular joint injury on both conventional 2D images and 3D CS-SPACE images(κ>0.6),and there was a high consistency in the evaluation of acromioclavicular joint injury between the two groups of images(κ >0.6). Conclusion:For the diagnosis of acromioclavicular joint injury,3D CS-SPACE sequence images has high consistency with conventional 2D images,and 3D CS-SPACE sequence can shorten the scanning time and obtain better image quality.

    参考文献
    相似文献
    引证文献
引用本文

赵如盛,王梦悦,徐露露,徐磊,郝绍伟,邹月芬.基于压缩感知的3D CS⁃SPACE序列在肩锁关节损伤诊断中的应用价值[J].南京医科大学学报(自然科学版),2024,(9):1250-1256

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2024-05-08
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2024-09-13
  • 出版日期:
通知关闭
郑重声明