基于Swin Transformer的低活度PET影像质量恢复方法研究
作者:
作者单位:

南京医科大学第一附属医院核医学科,江苏 南京 210029

作者简介:

通讯作者:

中图分类号:

R814.42

基金项目:

国家自然科学基金青年基金(12405387);江苏省基础研究计划自然科学基金青年基金(BK20241107);江苏省卫生健康委科研课题(Ym2023101)


Research on low⁃activity PET image quality restoration method based on Swin Transformer
Author:
Affiliation:

Department of Nuclear Medicine,the First Affiliated Hospital of Nanjing Medical University,Nanjing 210029 ,China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:探究氟代脱氧葡萄糖(fludeoxyglucose,18F-FDG)(活度对正电子发射计算机断层成像(positron emission tomog- raphy,PET)CT影像质量的影响规律,建立PET影像质量恢复方法实现对患者的辐射防护。方法:基于 Swin Transformer 全局特征识别低活度 PET 影像质量恢复深度学习网络 SwinUNetR-GAN,随机选择于 2024 年行 18F-FDG PET/CT检查的124例患者影像,探究不同给药活度下PET影像质量下降规律,并基于SwinUNetR-GAN网络实现低活度 PET 影像质量的恢复。结果:随着18F-FDG活度的降低,患者PET影像中正常组织及肿瘤病灶内的标准摄取值(standard uptake value,SUV)均值(SUVmean) 和最大值(SUVmax)均呈现增大趋势,当将18F-FDG的注射活度降低到临床现行活度的10%时,肿瘤病灶的SUVmean增大了约 1.1倍,而SUVmax增大了约2.0倍。此外,采用SwinUNetR-GAN网络可降低10%活度PET影像的噪声,绝对偏差由0.21降低至 0.15,相对偏差可由0.33降低至约0.25。结论:明确了18F-FDG活度对患者PET影像中正常组织及肿瘤组织定量参数的变化规律,提出了专用于低18F-FDG活度PET影像质量恢复的SwinUNetR-GAN网络,实现了降低患者所受辐射剂量的同时确保PET 影像的疾病诊断性能。

    Abstract:

    Objective:To explore the influence of 18F-FDG activity on PET/CT image quality and establish a PET image quality restoration method to achieve radiation protection for patients. Methods:A deep learning network SwinUNetR -GAN for restoring the quality of low - activity PET images based on the global feature recognition of Swin Transformer was established. The images of 124 patients who underwent 18F-FDG PET/CT examinations in 2024 were randomly selected to explore the law of PET image quality degradation under different activities of 18F-FDG and the quality of low-activity PET images was achieved based on the SwinUNetR- GAN network. Results:As the activity of 18F-FDG decreases,the mean and maximum values of the standard uptake value(SUV) (SUVmean and SUVmax)in normal tissues and tumor lesions in the PET images show an increasing trend. When the activity of 18F - FDG is reduced to 10% of the current clinical activity,the SUVmean of the tumor lesion increases by about 1.1 times,while the SUVmax increases by about 2.0 times. In addition,the use of the SwinUNetR-GAN network can reduce the noise of 10% activity PET images,The absolute deviation decreased from 0.21 to 0.15,and the relative deviation could be reduced from 0.33 to about 0.25. Conclusion:This study clarifies the change law of quantitative parameters of normal tissues and tumor tissues in patient PET images under activity of 18F-FDG and then,SwinUNetR -GAN network dedicated to low 118F-FDG activity PET image quality restoration is proposed,which could achieve the disease diagnosis performance of PET images while reducing the radiation dose deposited in patient.

    参考文献
    相似文献
    引证文献
引用本文

丁威,唐立钧,田锋.基于Swin Transformer的低活度PET影像质量恢复方法研究[J].南京医科大学学报(自然科学版),2025,45(11):1649-1655

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-07-28
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-11-12
  • 出版日期:
关闭