基于双层探测器CT引导标注的3D nnU-Net模型在非增强CT食管分割中的应用:与Total Segmentator模型的对比研究
作者:
作者单位:

1南京医科大学第四附属医院放射科,江苏 南京 210031 ; 2. 东南大学附属中大医院放射科,江苏 南京 210009

作者简介:

通讯作者:

中图分类号:

基金项目:

南京江北新区重点研发项目计划(ZDYF202520);南京医科大学科技发展基金一般项目(NMUB20250298)


Application of 3D nnU - Net model guided by dual - layer detector CT annotation in esophagus segmentation on non - contrast CT: a comparative study with the total segmentator model
Author:
Affiliation:

1Department of Radiology, the Fourth Affiliated Hospital of Nanjing Medical University, Nanjing 210031 ; 2. Department of Radiology, Zhongda Hospital, Southeast University, Nanjing 210009 , China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:针对非增强CT(non-contrast computed tomography,NCCT)食管组织对比度低、分割难度大、通用分割模型性能受限的临床难点,探索基于双层探测器CT(dual-layer computed tomography,DLCT)引导标注的3D无新U-Net(no new U-Net,nnU-Net)模型,提升NCCT食管分割的精度与泛化能力,并与Total Segmentator通用模型进行性能对比。方法:回顾性纳入南京医科大学第四附属医院300例胸部DLCT检查患者,融合虚拟平扫(virtual non-contrast,VNC)与增强图像完成食管人工分割金标准,并用VNC训练3D nnU-Net模型,以真实平扫(true non-contrast,TNC)作为内部验证集;另纳入东南大学附属中大医院100例NCCT、国家生物信息中心48例NCCT作为2个外部测试集。采用Dice相似系数(Dice similarity coefficient,DSC)、95%豪斯多夫距离(95% Hausdorff distance,HD95)、组内相关系数(Intraclass correlation coefficient,ICC)及Likert 5分法主观评分,对比两模型的分割性能。结果:在内部验证集及2个独立外部测试集中,3D nnU-Net模型的核心分割性能(DSC:0.756~0.798,HD95:4.00~4.10 mm)均显著优于Total Segmentator模型(DSC:0.687~0.697,HD95:5.00~5.00 mm;Z=3.875~13.045,P<0.001)。该模型与人工勾画金标准的一致性更佳(Spearman rs=0.821~0.887,ICC=0.84~0.91),显著高于对照模型(Spearman rs=0.626~0.716,ICC=0.64~0.70);Bland-Altman分析显示其95%一致性界限更窄,测量偏移更小,体积偏差处于临床可接受范围。同时,3D nnU-Net模型的主观分割质量评分稳定为5.00分,显著高于对照模型(P<0.001)。结论:基于DLCT引导标注的3D nnU-Net模型在食管分割中具有更优的分割性能与泛化能力,为NCCT自动化分割提供了新的技术策略。

    Abstract:

    Objective: To address the clinical challenges of poor esophageal tissue contrast, inherent segmentation difficulty, and suboptimal performance of generic segmentation models on non-contrast computed tomography (NCCT), this study developed a dual-layer computed tomography (DLCT) annotation-guided 3D no new U-Net (3D nnU-Net) model to improve the accuracy and generalizability of NCCT-based esophageal segmentation, and compared its performance with the widely used generic model Total Segmentator. Methods: A total of 300 patients who underwent chest DLCT examination at the Fourth Affiliated Hospital of Nanjing Medical University were retrospectively enrolled. The manual esophageal segmentation gold standard was established by fusing virtual non-contrast (VNC) and contrast-enhanced CT images. The 3D nnU-Net model was trained on VNC images, with true non-contrast (TNC) images serving as the internal validation set. Two independent external test sets were included: 100 NCCT cases from Zhongda Hospital Affiliated to Southeast University, and 48 NCCT cases from the National Center for Bioinformation. Segmentation performance of the two models was compared via quantitative metrics (Dice similarity coefficient, DSC; 95% Hausdorff distance, HD95; intraclass correlation coefficient, ICC) and qualitative 5-point Likert subjective scoring. Results: Across the internal validation set and two external test sets, the proposed 3D nnU-Net model achieved excellent core segmentation performance (DSC: 0.756-0.798, HD95: 4.00-4.10 mm), and significantly outperformed the Total Segmentator model (DSC: 0.687-0.697, HD95: 5.00~5.00 mm; Z=3.875-13.045, all P < 0.001). The proposed model exhibited stronger agreement with the manual gold standard (Spearman rs=0.821-0.887, ICC=0.84-0.91), markedly higher than the control model (Spearman rs=0.626-0.716, ICC=0.64-0.70). Bland-Altman analysis confirmed the 3D nnU-Net model had narrower 95% limits of agreement and smaller measurement bias, with volumetric deviation within the clinically acceptable range. Meanwhile, the proposed model yielded a stable median subjective segmentation quality score of 5.00, significantly higher than that of the control model (P < 0.001). Conclusion: The DLCT annotation-guided 3D nnU-Net model achieves superior esophageal segmentation performance and generalization capability, providing a novel technical strategy for automated NCCT-based esophageal segmentation.