Application Study on Improving Thyroid CT Image Quality Using Surgical Shoulder Pillow
Author:
Affiliation:

Fund Project:

The National Natural Science Foundation of China (General Program); Natural Science Foundation of JiangSu Province (General Program)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    [摘要] 目的 探讨基于手术肩枕的改良体位在优化甲状腺CT图像质量中的价值。 方法 前瞻性纳入176例拟行CT检查的甲状腺结节患者,分为对照组(常规体位,n=88)和实验组(改良体位,n=88)。对照组采用标准摆位法,患者呈仰卧位,双臂置于身体两侧,自然下垂;实验组采用手术肩枕垫高肩部,双肩与肩枕上缘平行,双臂置于身体两侧,头呈过伸位。比较两组动脉期和静脉期CT图像的主观质量评分(整体图像质量、主观噪声评价、伪影)、客观质量评分(信噪比SNR、对比噪声比CNR)及辐射剂量(CT剂量指数CTDIvol/mGy、剂量长度乘积DLP/mGy·cm、有效剂量ED/mSv)。 结果 主观图像质量评分方面,实验组在图像整体质量(Z=-5.385,P<0.001)、主观噪声(Z=-5.609,P<0.001)及伪影抑制(Z=-3.473,P=0.001)方面均优于对照组。客观图像质量评分方面,实验组动脉期SNR(Z=-6.533,P<0.001)、CNR(Z=-6.475,P<0.001)和静脉期SNR(t=-7.193,P<0.001)、CNR(Z=-5.705,P<0.001)均显著高于对照组。辐射剂量方面,实验组与对照组动脉期CTDIvol(Z=-0.527,P=0.598)、DLP(Z=-1.493,P=0.136)、ED(Z=-1.493,P=0.136)和静脉期CTDIvol(Z=-0.611,P=0.541)、DLP(Z=-1.151,P=0.250)、ED(Z=-1.151,P=0.250)差异均无统计学意义。 结论 基于手术肩枕的改良体位可充分拉伸患者颈部,在不增加辐射剂量的前提下改善甲状腺CT图像质量。

    Abstract:

    [ABSTRACT] Objective: To investigate the value of a modified position utilizing surgical shoulder pillows in optimising the quality of thyroid CT images. Methods: A total of 176 patients who intended to get a CT scan for evaluating thyroid nodules were prospectively enrolled, and divided into control group (conventional position, n=88) and experimental group (modified position, n=88). The patients in the control group were positioned in the supine position with their arms on each side of their bodies and drooping naturally. The experimental group was adopted with the shoulders elevated by the surgical shoulder pillows, shoulders parallel to the upper edge of the shoulder pillows, arms placed on each side of the body, and the head in the hyperextension position. Subjective quality scores (overall image quality, subjective noise evaluation, artefacts), objective quality scores (signal-to-noise ratio SNR, contrast-to-noise ratio CNR) and radiation doses (CT dose index CTDIvol/ mGy, dose length product DLP/ mGy·cm, effective dose ED/ mSv) of arterial-phase and venous-phase CT images were compared between two groups. Results: The experimental group outperformed the control group in subjective picture quality scores, demonstrating superiority in overall image quality (Z=-5.385, P<0.001), subjective noise (Z=-5.609, P<0.001), and artefact suppression (Z=-3.473, P=0.001). The experimental group exhibited much superior SNR and CNR than control group in both arterial (SNR: Z=-6.533; CNR: Z=-6.475; both P<0.001) and venous phases (SNR: t=-7.193; CNR: Z=-5.705; both P<0.001). No significant differences in radiation dose were observed between the experimental and control groups for arterial phase CTDIvol (Z=-0.527, P=0.598), DLP (Z=-1.493, P=0.136), ED (Z=-1.493, P=0.136), and venous phase CTDIvol (Z=-0.611, P=0.541), DLP (Z=-1.151, P=0.250), and ED (Z=-1.151, P=0.250). Conclusion: The modified position utilising surgical shoulder pillows allows patients to fully stretch their necks, and improves the quality of CT images of the thyroid gland without increasing the radiation dose.

    参考文献
    相似文献
    引证文献
引用本文
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-07-27
  • 最后修改日期:2025-09-08
  • 录用日期:2025-12-26
  • 在线发布日期:
  • 出版日期:
关闭