基于双层探测器CT引导标注的3D nnU-Net模型在非增强CT食管分割中的应用:与Total Segmentator模型的对比研究
DOI:
作者:
作者单位:

1.南京医科大学第四附属医院;2.东南大学附属中大医院

作者简介:

通讯作者:

中图分类号:

基金项目:

] 南京江北新区重点研发项目计划(ZDYF202520);南京医科大学科技发展基金一般项目(NMUB20250298)


Application of 3D nnU-Net Model Guided by Dual-Layer Detector CT Annotation in Esophagus Segmentation on Non-Contrast CT: A Comparative Study with the Total Segmentator Model
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 针对非增强CT(non-contrast CT, NCCT)食管组织对比度低、分割难度大、通用分割模型性能受限的临床痛点,探索基于双层探测器CT(dual-layer CT, DLCT)引导标注的3D nnU-Net模型,提升NCCT食管分割的精度与泛化能力,并与Total Segmentator通用模型进行性能对比。方法 回顾性纳入南京医科大学第四附属医院300例胸部DLCT检查患者,融合虚拟平扫(virtual non-contrast, VNC)与增强图像完成食管金标准手动分割,并用VNC训练3D nnU-Net模型,真实平扫(ture non-contrast, TNC)为内部验证集;另纳入东南大学附属中大医院100例NCCT、国家生物信息中心48例NCCT作为2个外部测试集。采用Dice相似系数(Dice similar coefficient,DSC)、95%豪斯多夫距离(95% Hausdorff distance, HD95)、一致性分析及Likert5分法主观评分,对比两模型的分割性能。结果 内部验证集及2个外部测试集1中,本模型DSC为0.756-0.798、HD95为4.00-4.10mm,均显著优于Total Segmentator模型(P<0.001);其与金标准的一致性(R<sub>s</sub><sub>pearman</sub>=0.821-0.887)与主观评分(5.00-5.00)也均显著高于对照模型。结论 基于DLCT引导标注的3D nnU-Net模型在食管分割中具有更优的分割性能与泛化能力,为NCCT自动化分割提供了新的技术策略。

    Abstract:

    Objective To address the clinical challenges of low tissue contrast, difficult segmentation, and limited performance of general segmentation models for esophagus on non-contrast CT (NCCT), this study aimed to develop a 3D nnU-Net model guided by dual-layer CT (DLCT) annotation to improve the accuracy and generalization ability of esophagus segmentation on NCCT, and to compare its performance with the Total Seg mentator general model. Methods A total of 300 patients who underwent chest DLCT examinations at the Fourth Affiliated Hospital of Nanjing Medical University were retrospectively enrolled. Manual gold-standard segmentation of the esophagus was performed by fusing virtual non-contrast (VNC) and enhanced images. A 3D nnU-Net model was trained using VNC images, with true non-contrast (TNC) images as the internal validation set. Additionally, 100 NCCT cases from Zhongda Hospital, Southeast University, and 48 NCCT cases from the China National Center for Bioinformation were included as two external test sets. The Dice similarity coefficient (DSC), 95% Hausdorff distance (HD95), consistency analysis, and 5-point Likert subjective scoring were used to compare the segmentation performance of the two models. Results In the internal validation set and the first external test set, the proposed model achieved a DSC of 0.756–0.798 and an HD95 of 4.00–4.10 mm, which were significantly superior to those of the Total Segmentator model (P<0.001). Its consistency with the gold standard (r?=0.821–0.887) and subjective scores (5.00–5.00) were also significantly higher than those of the control model. Conclusion The 3D nnU-Net model based on DLCT-guided annotation demonstrates superior segmentation performance and generalization ability in esophagus segmentation, providing a novel technical strategy for automated NCCT segmentation.

    参考文献
    相似文献
    引证文献
引用本文
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-04-09
  • 最后修改日期:2026-06-30
  • 录用日期:2026-11-04
  • 在线发布日期:
  • 出版日期:
关闭