Effects of Micro-Monovision Design Combined with Extended Depth of Focus Intraocular Lens Implantation on Visual Function in Patients Undergoing Phacoemulsification for Cataract
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的 评估微单视设计联合连续视程(EDOF)人工晶状体(IOL)植入术对白内障超声乳化患者视功能的影响。方法 连续纳入2024年06月至2025年08月南京医科大学附属无锡人民医院眼科收治的接受白内障超声乳化吸除联合人工晶体植入术的患者90例,通过随机数字表法将患者分为观察组(n=45)及对照组(n=45)。观察组接受微单视设计联合EDOF人工晶体植入术,对照组接受三焦点人工晶体植入术。观察并比较两组术后6个月的裸眼视力、视觉质量、离焦情况、对比敏感度及脱镜情况;同时收集患者随访期间不良视觉现象。结果 (1)两组患者临床基线资料无显著差异性(均P>0.05);(2)两组患者术前VF-14评分无显著统计学差异(P>0.05);术后观察组VF-14评分大于对照组,且两组术后VF-14评分均高于同组术前(均P<0.05);(3)观察组的离焦曲线显示,在0.50 D至-0.50 D的屈光度范围内,其裸眼远视力表现优异;在-1.00 D至-2.00 D范围内,其裸眼中视力表现尚可;在-2.50 D至-3.50 D范围内,其裸眼近视力表现良好;对照组中,从0.50 D至-0.50 D的屈光度范围内,裸眼远视力表现良好;从-2.50 D至-4.00 D范围内,裸眼近视力表现良好,其在-0.50 D至-2.50 D范围内保持了良好的裸眼中视力;比较可知,0.50 D至-0.50 D的屈光度范围内,观察组视力高于对照组;(4)不同明视、暗视条件及空间频率下观察组CS均高于对照组,差异均存在统计学意义;(5)观察组术后脱镜率高于对照组,但不良视觉现象发生率低于对照组;差异均存在统计学意义(均P<0.05)。结论 微单视设计能够提高白内障超声乳化联合EDOF人工晶体植入术患者裸眼中、近视力且视力表现更稳定,该方案能够提供更优的视觉质量、更佳的对比敏感度功能,提高术后患者脱镜率、降低术后不良视觉现象风险,是白内障患者的优化手术策略之一。

    Abstract:

    Objective To evaluate the effects of micro-monovision design combined with extended depth of focus (EDOF) intraocular lens (IOL) implantation on visual function in patients undergoing phacoemulsification for cataract. Methods A total of 90 patients who underwent phacoemulsification and IOL implantation in the department of Ophthalmology, Affiliated Wuxi People’s Hospital of Nanjing Medical University Hospital between June 2024 and August 2025 were consecutively enrolled. Patients were randomly assigned via a random number table to an observation group (n=45) and a control group (n=45). The observation group underwent micro-monovision design combined with EDOF IOL implantation, while the control group underwent trifocal IOL implantation. Uncorrected visual acuity, visual quality, defocus curves, contrast sensitivity, and spectacle independence were observed and compared between the two groups at 6 months postoperatively. Adverse visual phenomena during follow-up were also recorded. Results (1) No significant differences were found in baseline clinical characteristics between the two groups (all P>0.05). (2) No significant difference was observed in preoperative VF-14 scores between the two groups (P>0.05). Postoperative VF-14 scores in the observation group were higher than those in the control group, and postoperative VF-14 scores in both groups were higher than their respective preoperative scores (all P<0.05). (3) The defocus curve of the observation group demonstrated excellent uncorrected distance visual acuity (UDVA) within the diopter range of +0.50 D to -0.50 D, acceptable uncorrected intermediate visual acuity (UIVA) within -1.00 D to -2.00 D, and good uncorrected near visual acuity (UNVA) within -2.50 D to -3.50 D. In the control group, good UDVA was maintained from +0.50 D to -0.50 D, good UNVA was maintained from -2.50 D to -4.00 D, and good UIVA was maintained from -0.50 D to -2.50 D. Comparison revealed that visual acuity within the +0.50 D to -0.50 D range was higher in the observation group than in the control group. (4) Contrast sensitivity (CS) under various photopic, mesopic conditions and spatial frequencies was significantly higher in the observation group compared to the control group (all P<0.05). (5) The postoperative spectacle independence rate was higher in the observation group, while the incidence of adverse visual phenomena was lower, with both differences being statistically significant (all P<0.05). Conclusion The micro-monovision design can improve uncorrected intermediate and near visual acuity and provide more stable visual performance in patients undergoing phacoemulsification combined with EDOF IOL implantation. This approach offers superior visual quality, better contrast sensitivity function, a higher rate of postoperative spectacle independence, and a lower risk of adverse visual phenomena, making it an optimized surgical strategy for cataract patients.

    参考文献
    相似文献
    引证文献
引用本文
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2026-04-16
  • 最后修改日期:2026-09-19
  • 录用日期:2026-11-05
  • 在线发布日期:
  • 出版日期:
关闭