    摘要:

    目的:评估经食管超声心动图(TEE)左室流出道(LVOT)测量心脏排血量(COLVOT)和经Swan-Ganz肺动脉导管测量心脏排血量(COPAC)的一致性及左室射血分数(LVEF)-左室面积变化分数(LVFAC)-右室射血分数(RVEF)之间的相关性-方法:择期行冠状动脉旁路移植术的患者12例,性别不限,年龄18~70岁,体重56~84 kg,ASA分级Ⅱ或Ⅲ级,术前NYHA心功能分级Ⅱ级或Ⅲ级-麻醉诱导及术中维持均采用全静脉麻醉-麻醉诱导气管插管后置入Swan-Ganz肺动脉导管并放置TEE探头,于插管后(T0)-停止体外循环转机后或非体外循环手术血管吻合完成后15 min(T1)-30 min(T2)和60 min(T3)的数据-统计分析采用Bland-Altman 一致性检验和Pearson相关系数检验-结果:COPAC为(4.82 ± 1.32)L/min,COLVOT为(4.57 ± 1.30)L/min,两者具有良好的相关性(r = 0.655,P < 0.001),COPAC和COLVOT的偏差为0.28 L/min(95%CI为-0.04~0.60 L/min),一致性界限为-1.90~2.46 L/min-LVEF与LVFAC呈正相关(r = 0.662,P < 0.001),而与RVEF 无相关性(r = -0.218,P >0.05)-LVEF与LVFAC偏差为15.36%(95%CI为12.46%~18.29%),一致性界限为4.68%~35.43%,LVEF与RVEF的偏差为34.40%(95%CI为29.69%~39.10%),一致性界限为-2.01%~66.78%-结论:TEE经左室流出道测量心脏排血量和Swan-Ganz肺动脉导管测量心脏排血量之间有较强的相关性但一致性较差,TEE和PAC不能互相替代,而左室射血分数与左室面积变化分数之间存在明显偏差但有较好的相关性-

    Abstract:

    Objective:To determine if the cardiac output (CO) measured by transesophageal echocardiography (TEE) through the left ventricular outflow tract (LVOT) is consistent with that measured by pulmonary artery catheter (PAC). The correlation between left ventricular ejection fraction (LVEF),left ventricular fractional area change (LVFAC) and right ventricular ejection fraction (RVEF) was analyzed. Methods:Twelve patients with ASA Ⅱ~Ⅲ(NYHA Ⅱ or Ⅲ),aged 18~70 years,weighing 46~72 kg and undergoing coronary artery bypass grafting were studied. Anesthesia induction and intraoperative maintenance were performed by intravenous anesthesia. After tracheal intubation,the Swan-Ganz catheter and TEE probe were placed. The data were measured and recorded after tracheal intubation (T0),15 (T1),30 (T2) and 60 (T2) min after termination of cardiopulmonary bypass (CPB) or finished vascular anastomosis in off-pump CABG. Statistical analysis was performed by Bland-Altman plot and Pearson correlation coefficient method. Results:COPAC was (4.82 ± 1.32) L/min and COLVOT was (4.57 ± 1.30)L/min. COLVOT was highly correlated with COPAC (r = 0.655,P < 0.001). The bias between COPAC and COLVOT was 0.28 L/min (95%CI:-0.04~0.60 L/min),and limits of agreement were -1.90~2.46 L/min. LVEF was positively correlated with LVFAC (r = 0.662,P < 0.001),while it was not significantly correlated with RVEF (r = -0.218,P > 0.001). The bias between LVEF and LVFAC was 15.36% (95%CI:12.46%~18.29%),and limits of agreement was 4.68%~35.43%,while that between LVEF and RVEF was 34.40% (95%CI:29.69%~39.10%),and limits of agreement was -2.01%~66.78%. Conclusion:The results showed that CO measured by TEE through the LVOT was significantly correlated but poorly consistent with that measured by Swan-Ganz PAC. Both methods for CO measurement cannot replace each other. Moreover,there was an obviously bias but a good correlation between LVFAC and LVFAC.

    参考文献
    相似文献
    引证文献
引用本文

缪娟娟,史宏伟,王振红,赵雅梅,葛亚力,魏海燕.两种方法评估冠状动脉旁路移植术患者心脏收缩功能的比较[J].南京医科大学学报(自然科学版),2014,(7):981-985-990

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2013-11-21
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2014-07-05
  • 出版日期:
通知关闭
郑重声明