Application of ultrasound elastic strain ratio in diagnosing thyroid nodules of TI-RADS 4-6 categories
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:探讨超声弹性应变率比值在TI-RADS 4~6类甲状腺结节中的应用价值。方法:常规超声观察303例(共324个结节)甲状腺结节的二维声像图特征,依据甲状腺影像数据报告与评分系统(TI-RADS)对甲状腺结节进行分类,并进行超声弹性成像,绘制ROC曲线确定弹性应变率比值最佳鉴别诊断界值。将137个TI-RADS 4~6类甲状腺结节分组:Ⅰ组TI-RADS 4A类,Ⅱ组TI-RADS 4B类,Ⅲ组TI-RADS 5~6类(6类中除去已经病理证实者),分析弹性应变率比值在3组病例中的应用价值。结果:弹性应变率比值最佳界值为0.55,弹性应变率比值在Ⅰ组中差异无统计学意义,在Ⅱ-Ⅲ组中差异具有统计学意义。弹性应变率比值鉴别诊断Ⅱ组和Ⅲ组的敏感性-特异性-准确性-阳性预测值分别为90.9%-75.0%-87.5%-93.0%(Ⅱ组)和85.7%-80.0%-84.6%-94.7%(Ⅲ组)。结论:对于Ⅱ-Ⅲ组,联合应用TI-RADS分类系统与弹性应变率比值具有较高的应用价值,提示恶性结节应少用细针穿刺活检等其他检查,早期进行手术治疗;对于Ⅰ组,弹性应变率应用价值有限,应尽早结合其他检查手段以免延误诊断。

    Abstract:

    Objective:To explore the application value of ultrasound elastic strain ratio in diagnosing thyroid nodules of TI-RADS 4-6 categories. Methods:Conventional ultrasound was applied to 324 thyroid nodules (from 303 patients) to observe their two-dimensional ultrasonographic characteristics. The 324 thyroid nodules were classified into different groups according to the TI-RADS,and then undergone ultrasonic elastography and the strain ratios of them were recorded. A receiver-operating characteristic curve(ROC)was used to identify the cut-off point in the differential diagnosis of thyroid nodules. The 137 thyroid nodules of TI-RADS 4-6 categories were classified into three groups to analyze the application value of strain ratio in each group:group Ⅰ,TI-RADS 4A category;group Ⅱ,TI-RADS 4B category;group Ⅲ,TI-RADS 5-6 categories (the pathologically confirmed cases in category 6 have been removed). Results:The best boundary value of strain ratio was 0.55. The difference of strain ratio in group I was not statistically significant,while those in group Ⅱ and group Ⅲ were statistically significant. The sensitivity,specificity,accuracy and positive predictive value in group Ⅱand group Ⅲ were 90.9%,75.0%,87.5%,93.0% and 85.7%,80.0%,84.6%,94.7%,respectively. Conclusion:The combination of TI-RADS classification system and strain ratio in group Ⅱ and group Ⅲ was of high application value,which suggests that the malignant nodules should be given early surgical treatment in stead of examination like fine needle aspiration biopsy. While in group I,the application value of strain ratio was limited,thus other examination methods should be used at the same time as early as possible to avoid delays in the diagnosis of nodules.

    参考文献
    相似文献
    引证文献
引用本文

邓红艳,林红军,叶新华,邹月芬.超声弹性应变率比值在TI-RADS 4~6类甲状腺结节鉴别诊断中的应用[J].南京医科大学学报(自然科学版),2015,(3):421-424

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2014-08-15
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2015-03-10
  • 出版日期:
通知关闭
郑重声明