超声黏弹性成像瘤周参数对BI⁃RADS4类乳腺结节良恶性的预测价值
作者:
作者单位:

1南京医科大学附属无锡人民医院(南京医科大学无锡医学中心)超声医学科,江苏 无锡 214023 ; 2.南京医科大学附属南京医院心血管超声科,江苏 南京 210006 ; 3.南京医科大学附属无锡人民医院(南京医科大学无锡医学中心)检验科,4病理科,5乳腺外科,江苏 无锡 214023

作者简介:

通讯作者:

中图分类号:

R730.41

基金项目:

南京医科大学无锡医学中心队列与临床研究计划(WMCC202304)


The predictive value of ultrasound viscoelastic imaging peritumoral parameters for benign and malignant BI⁃RADS 4 breast nodules
Author:
Affiliation:

1Department of Ultrasound Medicine,the Affiliated Wuxi People’s Hospital of Nanjing Medical University(WuxiMedical Center,Nanjing Medical University),Wuxi 214023 ; 2.Department of Cardiovascular Ultrasound,theAffiliated Nanjing Hospital of Nanjing Medical University,Nanjing 210006 ; 3.Department of Laboratory Medicine,4Department of Pathology,5Department of Breast Surgery,the Affiliated Wuxi People’s Hospital of Nanjing MedicalUniversity(Wuxi Medical Center,Nanjing Medical University),Wuxi 214023 ,China

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:探讨黏弹性成像(viscoelasticity,VE)对乳腺影像报告和数据系统(breast imaging reporting and data system, BI-RADS)4类乳腺结节良恶性的预测价值。方法:回顾性分析2024年2月—2025年3月在南京医科大学附属无锡人民医院就诊的常规超声诊断BI-RADS 4类乳腺结节患者102例(共105个结节),应用VE和剪切波弹性成像(shear-wave elastography, SWE)测量乳腺结节超声参数,通过系统测量工具“Shell”,以1.0 mm为间隔,手动调整壳体厚度(n)为1.0~5.0 mm,获取瘤周 VE、SWE超声参数,比较两组超声参数的差异。绘制受试者工作特征(receiver operating characteristic,ROC)曲线分析 VE、SWE 超声参数及常规超声BI-RADS分类单独或联合预测BI-RADS 4类乳腺结节性质的诊断效能。结果:入选BI-RADS 4类乳腺结节105个,根据病理结果分为良性组58个,恶性组47个。两组SWE超声参数以Shell2.0剪切波弹性模量参数最大值(Emax)诊断价值最高,当截断值为89.48 kPa时,其预测BI-RADS 4类乳腺结节良恶性的曲线下面积(area under the curve,AUC)为0.709,灵敏度为53.20%,特异度为84.50%;两组VE超声参数以Shell3.0黏弹性参数最大值(Vmax)诊断价值最高,当截断值为5.77 Pa·s时,其预测BI-RADS 4类乳腺结节良恶性的AUC为0.750,灵敏度为70.21%,特异度为72.41%;将Shell2.0 Emax和Shell3.0 Vmax与 BI-RADS分类联合,预测BI-RADS 4类乳腺结节良恶性的AUC值提升至0.941,灵敏度高达93.60%,特异度也达到93.10%,差异具有统计学意义(P < 0.05)。结论:VE瘤周超声参数预测BI-RADS 4类乳腺结节良恶性具有较高的诊断价值,VE与SWE技术联合常规超声BI-RADS分类对BI-RADS 4类乳腺结节良恶性的诊断效能最佳。

    Abstract:

    Objective:To explore the predictive values of viscoelasticity(VE)for benign and malignant breast imaging reporting and data system(BI-RADS)4 breast nodules. Methods:A total of 102 patients(105 nodules)with BI-RADS 4 breast nodules diagnosed by conventional ultrasound in Wuxi People’s Hospital Affiliated to Nanjing Medical University from February 2024 to March 2025 were retrospectively analyzed. VE and shear -wave elastography(SWE)were used to measure ultrasound parameters. Through the system measurement tool“Shell”,the Shell thickness(n)was manually adjusted from 1.0 to 5.0 mm at an interval of 1.0 mm to obtain the peritumoral ultrasound parameters,and the differences of ultrasonic parameters between the two groups were compared. The receiver operating characteristic(ROC)curve was drawn to analyze the diagnostic efficacy of VE,SWE ultrasound parameters and conventional ultrasound BI-RADS classification alone or combined to predict the nature of BI-RADS 4 breast nodules. Results:A total of 105 BI-RADS 4 breast nodules were selected and divided into the benign group(n=58)and the malignant group(n=47)according to the pathological results. The diagnostic value of Shell2.0 maximum elastic modulus value(Emax)was the highest in the two groups of SWE ultrasound parameters. When the cutoff value was 89.48 kPa,its area under the ROC curve(AUC)for predicting the benign and malignant of BI-RADS 4 breast nodules was 0.709,the sensitivity was 53.20%,and the specificity was 84.50%. The diagnostic value of Shell3.0 maximum viscosity value(Vmax)was the highest in the two groups of VE ultrasound parameters. When the cutoff value was 5.77 Pa·s,its AUC for predicting the benign and malignant of BI -RADS 4 breast nodules was 0.750,the sensitivity was 70.21% ,and the specificity was 72.41% . When Shell2.0 Emax and Shell3.0 Vmax were combined with BI - RADS classification to predict the benign and malignant of BI -RADS 4 breast nodules,the AUC value increased to 0.941,with a sensitivity of 93.60% and a specificity of 93.10%,and the difference was statistically significant(P < 0.05). Conclusion:VE peritumoral parameters alone have high diagnostic value in predicting the benign and malignant of BI-RADS 4 breast nodules. VE,SWE technology combined with conventional ultrasound BI-RADS classification has the best diagnostic efficiency for the benign and malignant of BI-RADS 4 breast nodules.

    参考文献
    相似文献
    引证文献
引用本文

周锋盛,袁琳,浦浙宁,吴越,张雨,杨树东,秦安,张平洋.超声黏弹性成像瘤周参数对BI⁃RADS4类乳腺结节良恶性的预测价值[J].南京医科大学学报(自然科学版),2025,45(11):1563-1571

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2025-08-06
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2025-11-12
  • 出版日期:
关闭