131I-WBS与131I-SPECT/CT对分化型甲状腺癌诊治价值比较研究
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Comparison of 131I-WBS and 131I-SPECT/CT fusion imagings on management of patients with differentiated thyroid carcinoma
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:探讨131I全身显像(131I-WBS) 与131I单光子发射型计算机断层显像/计算机体层摄影术(131I-SPECT/CT)同机融合显像对于分化型甲状腺癌(DTC)术后131I治疗患者的诊治价值。方法:选择术后经病理证实并接受131I治疗的DTC 48例,3~5 d后同期行131I-WBS和131I-SPECT/CT断层融合显像。将131I-WBS与131I-SPECT/CT断层融合图像进行对比分析,探讨各自显像特点与临床价值。结果:48例DTC患者共行131I-WBS 48次,131I-SPECT/CT断层融合显像60次。在131I-WBS发现的总计145处摄碘灶中,甲状腺床占34.3%,恶性病灶占60.5%,非甲状腺生理性和良性病变摄取以及污染占5.2%。131I-SPECT/CT融合显像比131I-WBS多发现23处转移灶。在131I-WBS无法确诊的20例65处摄碘灶中,通过131I-SPECT/CT断层融合显像获得准确定位和定性诊断的分别占100%和94%。共使18例(37.5%,18/48)患者获得了更多的增益价值,且其中8例(44.4%,8/18)患者治疗方案发生了改变。结论:131I-WBS应常规应用于DTC术后131I治疗患者。当131I-WBS诊断不明确或者与临床表现不符时,加做 131I-SPECT/CT断层融合显像在提高DTC诊断正确率-制定和调整治疗方案上具有重要临床价值。

    Abstract:

    Objective:To explore the clinical values of 131I whole-body scan (131I-WBS) and 131I single photon emission computed tomography/computed tomography (131I-SPECT/CT) on the management of patients with differentiated thyroid carcinoma (DTC) after 131I therapy,respectively. Methods:After 3~5 days 131I therapy,48 DTC patients underwent 131I-WBS and 131I-SPECT/CT. The imaging features and clinical values of 131I-WBS and 131I-SPECT/CT were comparatively analyzed. Results:The patients had totally 48 131I-WBS and 60 131I-SPECT/CT. 145 foci were observed by 131I-WBS,including 34.3% of foci localized in the thyroid bed,60.5% of malignant lesions,and 5.2% caused by nonthyroid physiologic or benign uptake or a contaminant. There were 23 additional metastases detected by 131I-SPECT/CT. Futhermore,there were 20 patients whose 131I-WBS showed 65 inconclusive lesions. Precise localization and characterization by 131I-SPECT/CT fusion images were 65(100 %) and 61(94 %) of the 65 foci,respectively. 131I-SPECT/CT fusion images were considered to be of much benefit to 18(37.5%) of 48 patients. Changes of therapeutic plans happened to 8(44.4%) of 18 patients. Conclusion:131I-WBS should be routinely performed in the management of patients with DTC after 131I therapy. If 131I-WBS images were inconclusive or inconsistent with the clinical manifestations,131I-SPECT/CT must be required to increase the diagnostic accuracy and modulate therapeutic plans.

    参考文献
    相似文献
    引证文献
引用本文

李永军,徐兆强,柳 卫,程 旭,包丽华.131I-WBS与131I-SPECT/CT对分化型甲状腺癌诊治价值比较研究[J].南京医科大学学报(自然科学版),2013,(11):1608-1612

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2013-04-19
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2013-11-25
  • 出版日期: