基于压缩感知的心脏实时电影技术在评估左心房功能中的价值
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金(81701654,81601464)


The value of compressed sensing cardiac cine magnetic resonance imaging for analysis of left atrial function
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    目的:以传统的分层心脏电影成像(segmented cine imaging)为金标准,评估基于压缩感知(compressed sensing,CS)心脏实时电影在评价左心房功能中的价值。方法:纳入健康的志愿者40例和心超提示左心室舒张功能下降的心脏疾病患者31例,基于稳态平衡自由进动序列完成分层电影和CS实时电影的左心房数据采集,2名放射科医师独立对图像质量进行定性分析,并用CVI42图像后处理软件获得左心房径线、容积和射血分数(ejection fraction,EF),并同步进行定量分析。结果:CS电影和传统电影的图像质量无明显差异。两种电影获得左心房径线参数有较好的相关性(ICC>0.90)。除了主动射血分数外,两种电影获得的容积及射血分数均有较好的相关性(ICC>0.80)。两种电影获得的左心房二腔心和四腔心横径无明显差异。与金标准相比,CS电影高估了左心房最小容积,但是差距较小[(4.45±11.18)mL,P=0.003]。两种方法获得的左心房最大容积、收缩前容积和被动射血分数差异无统计学意义。CS电影能较好地区分正常人和左心房功能异常的患者。结论:,CS电影可用来准确分析左心房径线和容积,尤其是左心房被动射血分数。

    Abstract:

    Objective:This stndy aims to evaluate the value of compressed sensing(CS) cine cardiac magnetic resonance(CMR) for left atrial(LA)functional assessment compared with traditional segmented cine imaging(regarded as gold standard). Methods:Forty healthy volunteers and thirty-one patients with reduced left ventricular diastolic function by echocardiography underwent segmented cine and CS cine imaging with steady-state free-precession sequence to cover LA during CMR. LA diameter,volume and ejection fraction(EF)were evaluated by CVI42(circle cardiovascular imaging,Canada). Two radiologists independently performed qualitative analysis of image quality and quantitative analysis of all above LA parameters. Results:The image quality was no significant difference between traditional and CS cine. There was an excellent correlation for LA diameter(ICC>0.90) and good correlation for LA volume,EF between both cines(ICC>0.80),except for active EF. There were no significant difference in LA 2- and 4-chamber transverse diameters derived from both cines. Compared to the gold standard,the CS cine overestimated LA minimal volume,but the difference was small[(4.45±11.18)mL,P=0.003]. The LA maximal volume,pre-active volume and passive EF obtained by the two methods had no statistical difference. CS cine more accurately distinguished volunteers from patients with abnormal LA function than segmented cine. Conclusion:CS cine can be used to accurately evaluate LA diameter and volume for LA functional assessment,especially passive EF of LA.

    参考文献
    相似文献
    引证文献
引用本文

陈 杨,朱晓梅,秦 捷,祝因苏,徐 怡.基于压缩感知的心脏实时电影技术在评估左心房功能中的价值[J].南京医科大学学报(自然科学版),2021,(2):252-257

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2020-10-30
  • 最后修改日期:
  • 录用日期:
  • 在线发布日期: 2021-03-10
  • 出版日期: