Page 73 - 南京医科大学自然版
P. 73
第46卷第11期 南京医科大学学报(自然科学版)
2026年11月 Journal of Nanjing Medical University(Natural Sciences) ·1659 ·
·临床研究·
微单视设计联合景深延长型人工晶状体植入术对白内障超声
乳化患者视功能的影响
殷 丽,谢田华,刘艳秋,王 琰,姚 勇 *
南京医科大学附属无锡人民医院眼科,江苏 无锡 214023
[摘 要] 目的:评估微单视设计联合景深延长型(extended depth of focus,EDOF)人工晶状体(intraocular lens,IOL)植入术对
白内障超声乳化患者视功能的影响。方法:连续纳入2024年6月—2025年8月南京医科大学附属无锡人民医院眼科收治的接
受白内障超声乳化吸除联合IOL植入术的患者90例,通过随机数表法将患者分为观察组(n=45)及对照组(n=45)。观察组接
受微单视设计联合EDOF IOL植入术,对照组接受三焦点IOL植入术,比较两组术后6个月的裸眼视力、视觉质量、离焦情况、
对比敏感度(contrast sensitivity,CS)及脱镜情况,同时收集患者随访期间不良视觉现象。结果:两组患者临床基线资料及术前
视功能指数量表(VF⁃14)评分差异无统计学意义(P > 0.05);术后VF⁃14评分均高于同组术前(P均< 0.05);术后观察组VF⁃14
评分大于对照组。观察组的离焦曲线显示,在-0.50 D~0.50 D的屈光度范围内其裸眼远视力表现优异;在-2.00 D~-1.00 D范
围内其裸眼中视力表现尚可;在-3.50 D~-2.50 D范围内其裸眼近视力表现良好;对照组中,从-0.50 D~0.50 D的屈光度范围内
裸眼远视力表现良好;从-3.50 D~-2.50 D 范围内裸眼近视力表现良好,其在-2.00 D~-1.00 D 范围内保持了良好的裸眼中视
力;比较可知,-0.50 D~0.50 D的屈光度范围内,观察裸眼视力与对照组相仿。不同明视、暗视条件及空间频率下观察组CS均
高于对照组,差异均存在统计学意义。观察组术后脱镜率高于对照组,不良视觉现象发生率低于对照组(P均<0.05)。结论:微
单视设计能够提高白内障超声乳化联合EDOF IOL 植入术患者裸眼中、近视力且视力表现更稳定,该方案能够提供更优的视
觉质量、更佳的对比敏感度功能,提高术后患者脱镜率、降低术后不良视觉现象风险,是白内障患者的优化手术策略之一。
[关键词] 白内障;超声乳化;人工晶状体;微单视;三焦点人工晶状体;视功能
[中图分类号] R776 [文献标志码] A [文章编号] 1007⁃4368(2026)11⁃1659⁃07
doi: 10.7655/NYDXBNSN260482
Effects of micro ⁃ monovision design combined with extended depth of focus intraocular
lens implantation on visual function in patients undergoing phacoemulsification for cataract
Yin Li,Xie Tianhua,Liu Yanqiu,Wang Yan,Yao Yong *
Department of Ophthalmology,Wuxi People’s Hospital Affiliated of Nanjing Medical University,Wuxi 214023,China
[Abstract] Objective: To evaluate the effects of micro ⁃ monovision design combined with extended depth of focus(EDOF)
intraocular lens(IOL)implantation on visual function in patients undergoing phacoemulsification for cataract. Methods:A total of 90
patients who underwent phacoemulsification and IOL implantation in the department of Ophthalmology,Affiliated Wuxi People’s
Hospital of Nanjing Medical University Hospital between June 2024 and August 2025 were consecutively enrolled. Patients were
randomly assigned via a random number table to an observation group(n=45)and a control group(n=45). The observation group
underwent micro ⁃ monovision design combined with EDOF ⁃ IOL implantation,while the control group underwent trifocal IOL
implantation. Uncorrected visual acuity,visual quality,defocus curves,contrast sensitivity(CS),and spectacle independence were
observed and compared between the two groups at 6 months postoperatively. Adverse visual phenomena during follow⁃up were also
recorded. Results:No significant differences were found in baseline clinical characteristics and preoperative Visual Function Index
(VF⁃14)scores between the two groups(all P > 0.05). The postoperative VF⁃14 scores were significantly higher than the preoperative
values within each group(all P < 0.05). The postoperative VF⁃14 score was higher in the observation group than in the control group.
[基金项目] 江苏省医学重点学科(共建)(SQW⁃ZDXK)
通信作者(Corresponding author),E⁃mail: yongyao@njmu.edu.cn(ORCID:0000⁃0002⁃5506⁃7101)
∗