Page 74 - 南京医科大学自然版
P. 74

第46卷第11期
               ·1660 ·                           南 京    医 科 大 学 学         报                        2026年11月


              The defocus curve of the observation group demonstrated excellent uncorrected distance visual acuity(UDVA)within the diopter range
              of -0.50 D to 0.50 D,acceptable uncorrected intermediate visual acuity(UIVA)within -2.00 D to -1.00 D,and good uncorrected near
              visual acuity(UNVA)within -3.50 D to -2.50 D. In the control group,good UDVA was maintained from -0.50 D to 0.50 D,good
              UNVA was maintained from -3.50 D to -2.50 D,and good UIVA was maintained from -2.00 D to -1.00 D. Comparison revealed that
              the uncorrected visual acuity of the observation group within the -0.50 D to 0.50 D range was higher in the observation group than in
              the control group. CS under various photopic,mesopic conditions and spatial frequencies was significantly higher in the observation
              group thanin the control group(all P < 0.05). The postoperative spectacle independence rate was higher in the observation group,while
              the incidence of adverse visual phenomena was lower,with both differences being statistically significant(all P < 0.05). Conclusion:
              The micro⁃monovision design can improve uncorrected intermediate and near visual acuity and provide more stable visual performance
              in patients undergoing phacoemulsification combined with EDOF⁃IOL implantation. This approach offers superior visual quality,better
              contrast sensitivity function,a higher rate of postoperative spectacle independence,and a lower risk of adverse visual phenomena,

              making it an optimized surgical strategy for cataract patients.
             [Key words] cataract;phacoemulsification;intraocular lens;micro⁃monovision;trifocal intraocular lens;visual function
                                                                          [J Nanjing Med Univ,2026,46(11):1659⁃1665]






                  近年来,我国人口老龄化形势严峻,年龄相关
                                                                1  对象和方法
              性白内障位居致盲性眼病首位。目前该类患者的
              主流术式为超声乳化吸除联合人工晶状体(intraoc⁃                       1.1  对象
              ular lens,IOL)植入术 。随着患者对生活质量的要                         连续纳入2024年6月—2025年8月南京医科大
                                 [1]
              求提高,该疾病的治疗目标已由“复明”转化为“屈                           学附属无锡人民医院眼科收治的接受白内障超声
              光性矫正”。随着多焦点人工晶状体(如三焦点人工                           乳化吸除联合IOL植入的患者90例,通过随机数表
              晶体)的不断研发及临床应用,能够有效改善患者远、                          法将患者分为观察组(n=45)及对照组(n=45)。样
                                                      [2]
              近视力,在临床应用中获得了较高的脱镜率 。然                            本量估算依据:本研究为两组平行对照设计,设定
              而,其存在光线能量分散及离焦像等情况导致对比                            双侧检验α=0.05、检验效能 80%,基于既往文献及
              敏感度下降、眩光与光晕等视觉干扰,影响视觉舒                            预试验结果,主要结局指标两组预期均数差δ=6.0、
                    [3]
              适度等 ,临床应用受限。基于此有学者开发了景                            标准差σ=10.0,经两独立样本均数比较公式 n=2×
              深延长型人工晶状体(extended depth of field IOL,           (Z1-α/2+Z1-β)σ /δ 计算,每组需 44 例可评估受试
                                                                                  2
                                                                              2
                                                                                2
              EDOF IOL),其通过衍射光栅将光线能量集中于一                        者;考虑约 10%的脱落率,按 n′=n/(1-0.10)校正后
              个被延长的单一焦点上,实现了为患者提供从远距                            每组计划招募 50 例,预计脱落 5 例,最终每组纳入
              离到中距离平滑、连续视力的可能,同时保证了对                            45例可分析病例,总样本量90例。以实际纳入45例
              比敏感度,降低了眩光、光晕等不良视觉现象,但其                           复核,检验效能约 81%,满足预设要求。观察组:
                                                        [4-5]
              对更近距离视力的改善程度不及多焦点 IOL                        。    男27例,女18例,年龄(71.46±8.25)岁(68~85岁),病
              联合微单视设计可能是解决EDOF IOL 近视力局限                        程(6.02±2.18)年(4~11 年)。对照组:男 24 例,女
              的方案之一。EDOF IOL提供优异的远、中距离连续                        21 例,年龄(72.28±7.94)岁(63~87 岁),病程(5.83±
              视力及高视觉质量;微单视设计则通过微小的屈光                            2.21)年(3~9年)。
              差,弥补EDOF的延长焦深近距离视力的不足,为患                               纳入标准:①通过第 3 代晶状体混浊分类系统
              者提供全视程优化效果           [6-7] 。回顾既往研究可知,国           (lens opacities classification system Ⅲ,LOCS Ⅲ)系
              内学者的研究指出,微单视设计联合 EDOF⁃IOL 植                       统评估患者晶状体混浊程度需接受手术治疗;②患
              入能够有效改善白内障患者视觉质量及中、近视                             者同意接受白内障超声乳化吸除联合 IOL 植入手
              力,较单纯三焦点 IOL 植入能够更有效地改善患者                         术;③首次接受手术;④术前最佳矫正视力<0.5;
              视功能 。但是分析可知,上述研究对患者术后随访                           ⑤22.0 mm≤眼轴长度≤26.0 mm;⑥术前明确诊断患
                    [8]
              时间较短,仅关注了术后短期患者视功能的改善情                            者主视眼及非主视眼。排除标准:①合并其他眼部
              况,对此类患者术后长期视功能影响研究尚属空白。                           疾病,包括但不限于青光眼、活动性葡萄膜炎、糖尿病
   69   70   71   72   73   74   75   76   77   78   79