第46卷第4期 吴邦钰,王志霄,项景轩,等. 基于卷积神经网络的胃癌病理图像分类诊断与分级识别[J].
2026年4月 南京医科大学学报(自然科学版),2026,46(4):520-532 ·527 ·
表2 单模型分级性能
Table 2 Single⁃model grading performance
Network Accuracy(95%CI) Average sensitivity(95%CI) Average specificity(95%CI) Average F1⁃score(95%CI)
ResNet101 93.34(92.85-93.83) 92.91(92.41-93.44) 97.78(97.62-97.95) 93.02(92.52-93.53)
ResNet50 93.29(92.78-93.75) 92.84(92.31-93.34) 97.76(97.59-97.92) 92.97(92.43-93.45)
EfficientNetB0 93.11(92.60-93.57) 92.62(92.10-93.11) 97.71(97.54-97.87) 92.70(92.17-93.18)
DenseNet201 92.93(92.41-93.42) 92.55(92.00-93.10) 97.67(97.49-97.83) 92.54(91.98-93.06)
ResNet18 92.51(91.97-93.02) 92.04(91.49-92.58) 97.51(97.32-97.68) 92.16(91.61-92.69)
MobileNetV2 92.21(91.67-92.71) 91.71(91.16-92.24) 97.41(97.23-97.58) 91.80(91.25-92.32)
Darknet53 92.06(91.53-92.59) 91.47(90.90-92.03) 97.36(97.18-97.53) 91.67(91.11-92.23)
Xception 91.84(91.30-92.38) 91.47(90.90-92.04) 97.30(97.12-97.48) 91.50(90.93-92.06)
NASNetMobile 91.29(90.74-91.83) 90.57(89.96-91.15) 97.10(96.91-97.28) 90.80(90.22-91.37)
ShuffleNet 90.97(90.42-91.52) 90.34(89.74-90.93) 97.00(96.81-97.19) 90.49(89.89-91.07)
InceptionResNetV2 90.86(90.28-91.42) 90.49(89.91-91.07) 96.98(96.79-97.16) 90.43(89.84-91.01)
InceptionV3 90.61(90.04-91.16) 90.07(89.45-90.64) 96.88(96.69-97.06) 90.14(89.53-90.71)
VGG16 90.47(89.84-91.05) 90.01(89.42-90.61) 96.84(96.63-97.04) 90.07(89.47-90.66)
VGG19 89.97(89.40-90.56) 89.38(88.81-89.96) 96.66(96.46-96.85) 89.48(88.90-90.05)
GoogleNet 88.75(88.16-89.38) 88.15(87.53-88.82) 96.26(96.06-96.48) 88.26(87.66-88.91)
Darknet19 86.75(86.09-87.47) 85.65(84.95-86.38) 95.56(95.33-95.80) 85.98(85.26-86.71)
SqueezeNet 83.83(83.10-84.53) 82.97(82.22-83.72) 94.62(94.38-94.86) 83.18(82.41-83.91)
表3 集成模型性能指数
Table 3 Average performance index of ensemble models
Network Accuracy(95%CI) Average sensitivity(95%CI) Average specificity(95%CI) Average F1⁃score(95%CI)
Hard voting method 94.38(93.93-94.84) 93.98(90.23-97.72) 98.13(97.24-99.25) 94.08(91.14-97.34)
Random forest 95.06(94.64-95.47) 94.77(94.32-95.21) 98.36(98.23-98.50) 94.82(94.38-95.26)
癌 AUC=0.995(95% CI:0.994~0.996)。平均 AUC= 1.0
0.991(95%CI:0.990~0.992),显示优秀的识别性能。 0.9
2.3 真实场景模拟评估 0.8
0.7
挑选 TCGA 中的病理切片模拟真实场景处理,
进行端到端的诊断识别流程演示。输入需要识别 Sensitivity 0.6
0.5
的整张切片,模型开始切割,去除背景,保留组织部 0.4
Poorly differentiated
分。将组织部分细分切割后,第一个模型开始识 0.3 Well⁃differentiated
别,区分癌与非癌,用绿色表示非癌区块,红色表示 0.2 Moderately differentiated
Benign
癌区块,按识别结果重新拼接为大图,将识别结果可 0.1
Random classifier
视化。癌与非癌区分完成后,依照第一个模型的分类 0
0 0.2 0.4 0.6 0.8 1.0
标记提取癌区块部分,输入第2个模型,区分高分化、 1-Specificity
图7 分级模型的ROC曲线
中分化、低分化,用红色表示低分化,橙色表示中分
Figure 7 ROC curve of grading model
化,黄色表示高分化,同样按识别结果重新拼接为大
图,将识别结果可视化。由此完成整张切片的癌与非 时,可直接调用训练好的模型识别,计算成本与模
癌分类诊断与癌区域的分级识别,结果见图8。 型本身可学习的参数总数有关。若要利用 GPU 进
在实地场景应用时,也需考虑模型计算成本, 行加速,也可通过调整模型输入图片的 batchsize 来
前文中提到使用了 RTX4080 Laptop 训练模型,主要 调整显存占用。为评估计算成本,本研究统计每个
是使用 RTX4080 LaptopGPU 进行训练过程的加速, 模型的可学习参数总数对比图(图9)。由数据可知,
训练完成后,保存已经训练好的模型。当模型运行 大部分模型参数占用均在200 MB以下,部署计算成