               ·1400 ·                           南 京    医 科 大 学 学         报                        2022年10月


              行改性和修饰,如大颗粒喷砂⁃酸蚀、双酸酸蚀、阳极                               al. Influence of fluoride,hydrogen peroxide and lactic ac⁃
              氧化等   [33-35] 。考虑到这一点,不同形貌的钛表面在                        id on the corrosion resistance of commercially pure titani⁃
              模拟过氧化微环境下的腐蚀行为特征还有待于更                                  um[J]. Acta Biomater,2006,2(1):121-129
              深入的研究。                                            [9] YU X Y,ZHU W Q,CHEN W,et al. Osteoclast⁃mediated
                  综上所述,BSA 对纯钛表面天然氧化膜的稳定                             biocorrosion of pure titanium in an inflammatory microen⁃
                                                                     vironment[J]. Mater Sci Eng C Mater Biol Appl,2021,
              性无明显影响,模拟过氧化微环境中的H2O2会损害
                                                                     119:111610
              钛表面氧化膜,减弱钛的耐腐蚀性能,造成电化学
                                                                [10] CLARK G C,WILLIAMS D F. The effects of proteins on
              腐蚀和钛离子释放,而BSA与H2O2同时存在时,BSA                            metallic corrosion[J]. J Biomed Mater Res,1982,16(2):
              对 H2O2 引发的钛腐蚀行为具有一定的抑制作用。                              125-134
              本研究在体外模拟构建过氧化微环境,为深入探究                            [11] 王鲁宁,刘丽君,岩       雨,等. 蛋白质吸附对医用金属材
              钛种植体在体内的腐蚀行为提供实验依据。然而,                                 料体外腐蚀行为的影响[J]. 金属学报,2021,57(1):1-
              本研究中腐蚀测试采用的电解质溶液为静止态,而                                 15
              人体体液多处于流动态,这种流动态是否会对测试                            [12] TAKEMOTO S,HATTORI M,YOSHINARI M,et al. Cor⁃
              结果产生额外的影响尚未可知。在进一步的研究                                  rosion behavior and surface characterization of Ti⁃20Cr al⁃
              中,有必要模拟更真实的电解质物理状态来评估钛                                 loy in a solution containing fluoride[J]. Dent Mater J,
              表面特性及其腐蚀行为。                                            2004,23(3):379-386
                                                                [13] TAKEMOTO S,HATTORI M,YOSHINARI M,et al. Sup⁃
             [参考文献]
                                                                     pression of fluoride⁃induced corrosion of titanium by albu⁃
             [1] PJETURSSON B E,ASGEIRSSON A G,ZWAHLEN M,            min in oral modified environment[J]. J Biomed Mater
                   et al. Improvements in implant dentistry over the last de⁃  Res Part B Appl Biomater,2008,87(2):475-481
                   cade:comparison of survival and complication rates in  [14] CHENG X L,ROSCOE S G. Corrosion behavior of titani⁃
                   older and newer publications[J]. Int J Oral Maxillofac Im⁃  um in the presence of calcium phosphate and serum pro⁃
                   plants,2014,29(Suppl):308-324                     teins[J]. Biomaterials,2005,26(35):7350-7356
             [2] FUGAZZOTTO P A. Survival rates of 8⁃mm or shorter tis⁃  [15] XU W C,YU F,YANG L H,et al. Accelerated corrosion
                   sue⁃level implants in function for up to 228 months[J].  of 316L stainless steel in simulated body fluids in the
                   Int J Oral Maxillofac Implants,2020,35(6):1239-1247  presence of H2O2 and albumin[J]. Mater Sci Eng C Mater
             [3] SUITO H,IWAWAKI Y,GOTO T,et al. Oral factors        Biol Appl,2018,92:11-19
                   affecting titanium elution and corrosion:an in vitro study  [16] TARDELLI J D C,BOLFARINI C,DOS REIS A C. Com⁃
                   using simulated body fluid[J].PLoS One,2013,8(6):  parative analysis of corrosion resistance between beta tita⁃
                   e66052                                            nium and Ti ⁃ 6Al ⁃ 4V alloys:a systematic review[J]. J
             [4] KARIMI S,ALFANTAZI A M. Ion release and surface ox⁃  Trace Elem Med Biol,2020,62:126618
                   ide composition of AISI 316L,Co⁃28Cr⁃6Mo,and Ti⁃6Al⁃  [17] NOUMBISSI S,SCARANO A,GUPTA S. A literature re⁃
                   4V alloys immersed in human serum albumin solutions  view study on atomic ions dissolution of titanium and its
                  [J]. Mater Sci Eng C,2014,40:435-444               alloys in implant dentistry[J]. Materials,2019,12(3):
             [5] HAMEISTER R,KAUR C,DHEEN S T,et al. Reactive        368-368
                   oxygen/nitrogen species(ROS/RNS)and oxidative stress  [18] KIM K T,EO M Y,NGUYEN T T H,et al. General re⁃
                   in arthroplasty[J]. J Biomed Mater Res Part B Appl Bio⁃  view of titanium toxicity[J]. Int J Implant Dent,2019,5
                   mater,2020,108(5):2073-2087                      (1):10
             [6] GILBERT J L,SIVAN S,LIU Y P,et al. Direct in vivo in⁃  [19] CHEN W,ZHU W Q,QIU J. Impact of exogenous metal
                   flammatory cell⁃induced corrosion of CoCrMo alloy ortho⁃  ions on peri⁃implant bone metabolism:a review[J]. RSC
                   pedic implant surfaces[J]. J Biomed Mater Res A,2015,  Adv,2021,11(22):13152-13163
                   103(1):211-223                               [20] CHEN W Q,ZHANG S M,QIU J. Surface analysis and
             [7] AL⁃MOBARAK N A,AL⁃MAYOUF A M,AL⁃SWAYIH              corrosion behavior of pure titanium under fluoride expo⁃
                   A A. The effect of hydrogen peroxide on the electrochemi⁃  sure[J]. J Prosthet Dent,2020,124(2):239.e1-239.e8
                   cal behavior of Ti and some of its alloys for dental applica⁃  [21] ZHU W Q,SHAO S Y,XU L N,et al. Enhanced corrosion
                   tions[J]. Mater Chem Phys,2005,99(2):333-340      resistance of zinc⁃containing nanowires⁃modified titanium
             [8] MABILLEAU G,BOURDON S,JOLY⁃GUILLOU M L,et           surface under exposure to oxidizing microenvironment[J].
   53   54   55   56   57   58   59   60   61   62   63