Page 120 - 南京医科大学自然版
P. 120

第46卷第6期
               ·902  ·                           南 京    医 科 大 学 学         报                        2026年6月


                   of patients with midshaft clavicle fracture fixed with a  plate osteosynthesis(MIPO)technique for midshaft clavi⁃
                   locked plate via an open versus percutaneous approach[J].  cle fractures:a systematic review and meta⁃analysis[J].
                   Injury,2023,54(Suppl 6):110746                    JSES Int,2024,8(2):257-267
             [9] SISMAN A,POLAT O. Comparison of intramedullary nail⁃  [15]CHEN W,WANG B,LIU Z. A fluoroscopic view for mid⁃
                   ing and plate fixation in the surgical treatment of isolated  shaft clavicular fracture reduction and internal fixation:
                   fractures of the distal two⁃thirds of ulna diaphysis[J]. Jt  posteroanterior 25 degrees skyline projection[J]. BMC
                   Dis Relat Surg,2023,34(2):374-380                 Surg,2022,22(1):371
             [10]LI F,TAN Y,CUI L,et al. Efficacy and safety of volar  [16]KEIL H,VETTER S Y,GRÜTZNER P A,et al. Intraoper⁃
                   locking plate versus cast immobilization for distal radius  ative computed tomography in orthopaedic trauma sur⁃
                   fractures:a systematic review and meta ⁃ analysis of ran⁃  gery[J]. Zeitschrift Für Orthopädie Und Unfallchirurgie,
                   domized controlled trials[J]. J Plast Surg Hand Surg,  2021,160(4):407-413
                   2024,59:108-116                              [17]LEFAIVRE K A,SLOBOGEAN G,O’HARA N N,et al.
             [11]张    浩,方加虎,宋李军,等. 背侧入路治疗桡骨远端背                       Far cortical locking versus standard constructs for locked
                   侧不稳定骨折的疗效观察[J]. 南京医科大学学报(自                        plate fixation in the treatment of acute,displaced frac⁃
                   然科学版),2019,39(5):717-720                          tures of the distal femur:a multicenter randomized trial[J].
                   ZHANG H,FANG J H,SONG L J,et al. Observation of   J Bone Joint Surg Am,2024,106(19):1739-1749
                   the efficacy of dorsal approach in treating distal radius  [18]ZHAO D W,ZHANG T W,WANG W D,et al. Internal
                   fractures with dorsal instability[J]. Journal of Nanjing  fixation with biodegradable high purity magnesium screws
                   Medical University(Natural Sciences),2019,39(8):717-  in the treatment of ankle fracture[J]. J Orthop Translat,
                   720                                               2025,51:198-206
             [12]MILLER D L,GOSWAMI T. A review of locking compres⁃  [19]YEUNG C M,BHASHYAM A R,PATEL S S,et al. Car⁃
                   sion plate biomechanics and their advantages as internal  bon fiber implants in orthopaedic oncology[J]. J Clin
                   fixators in fracture healing[J]. Clin Biomech(Bristol),  Med,2022,11(17):4959
                   2007,22(10):1049-1062                        [20]LIN C C,WANG S P,LIN K J,et al. Mechanical optimiza⁃
             [13]ORTEGA⁃YAGO A,BALFAGON⁃FERRER A,BARRES⁃             tion of plate ⁃ screw interfaces in variable ⁃ angle locking
                   CARSI M,et al. Treating multifocal humerus fractures:a  systems:a parametric study[J]. Front Bioeng Biotechnol,
                   comparison between the mipo technique and intramedul⁃  2025,13:1681460
                   lary nailing[J]. Injury,2022,53(10):3332-3338  (收稿:2025-12-25;修回:2026-04-29;录用:2026-04-30)
             [14]LA BANCA V,LIMA GHV,VIGANO AVP,et al. Compli⁃                                (本文编辑:唐       震)
                   cations and clinical outcomes with minimally invasive
   115   116   117   118   119   120   121   122   123   124   125