Page 117 - 南京医科大学自然版
P. 117

第46卷第6期             姚 翔,苗 瀚,刘圣洁,等. 锁定接骨板“假锁”现象的新分型和上肢分布规律[J].
                  2026年6月                      南京医科大学学报(自然科学版),2026,46(6):894-902                      ·899  ·






                                                                                               a
                                                                                              b
                                                                                              b               b

                                                                                             b                b

                              A               B               C               D                E               F












                                              G               H               I               J               K
                   A:Preoperative X⁃ray. B:Preoperative CT. C,D:Intraoperative fluoroscopic images. E:Magnified view of the proximal fluoroscopy showing type A
               (a)and type B(b)pseudolock screws. F:Magnified view of the distal fluoroscopy showing both screws exhibiting type B(b)pseudolock. G:Photograph
                of multiple small incisions from the minimally invasive procedure. H-K:Images showing standard insertion depthand orientation of locking head screws
                in the locking compression plate.
                              图4 1例肱骨骨折微创手术病例,术中采用多处小切口置钉,多枚LHS发生了假锁现象
                Figure 4 A case of minimally invasive surgery for a humerus fracture demonstrating small incisions and pseudolocked screws








                                      A                       B                        C                       D






                                      E                       F                       G                        H
                   A:Routine anteroposterior shoulder X⁃ray. B:Photograph of the locking plate. C-H:Various angled fluoroscopic views of the plate surface,high⁃
                lighting the necessity of multi⁃angle imaging to verify that each screw is correctly and fully inserted.
                                 图5 1例锁骨锁定板接骨术后图像,多角度透视才能确认每个LHS是否标准置钉
                Figure 5  Postoperative images of clavicle locking plate osteosynthesis demonstrating the need for multiple angled perspec⁃
                        tives to confirm proper insertion of locking head screws

                    按各亚型分组,上肢长骨锁定板接骨术中,A型                         vs. 22.1% vs. 22.2%),组内差异无统计学意义。按侧
                假锁的上肢发生率最高,为(14.1%,1 646/11 636),                 别分组,左侧假锁发生率为 22.4%(1 434/6 388),右
                B 型次之(7.8%,911/11 636),而 C 型罕见(0.1%,              侧发生率为 21.5%(1 130/5 248),组间比较差异无
                7/11 636)。A、B 两型假锁占绝对主导地位,提示在                     统计学意义(P=0.235)。表明性别、年龄和侧别并非
                手术过程中,医生对于LHS的置入环节值得进一步                           上肢假锁分布差异的主要因素。
                规范操作。                                                 按骨骼类型分组,不同骨骼间存在明显差异:

                    按性别分组,男性病例的假锁发生率为 21.9%                       肱骨(25.0%,650/2 604)与尺骨(25.2%,198/785)的
               (1 368/6 245),女性病例为 22.2%(1 196/5 391),两           假锁发生率显著高于锁骨(21.3%,1401/6 565)与桡
                组差异无统计学意义(P=0.717)。按年龄分组,青年                       骨(18.7%,315/1 367)。肱骨和桡骨对比组、尺骨与

                组、中年组和老年组假锁发生率非常相近(21.6%                          桡骨对比组,两组皆存在统计学差异。这可能与肱
   112   113   114   115   116   117   118   119   120   121   122